logo

 

vlajka-cz vlajka-de vlajka-en

Single-phase transformers YVT
with voltage step control

 

Ordering Data

 

A YVT 230 / …
1,4 No. 10500
2,1 No. 10501
3,6 No. 10502
4,5 No. 10503
7,0 No. 10504
10,5 No. 10505
16,0 No. 10506
A YVT 400 / …
2,0 No. 10510
4,0 No. 10511
7,0 No. 10512
11,0 No. 10513
16,0 No. 10514
20,0 No. 10515

 

Optional standard
voltage rations:

230 Volts
/
0 – 80 – 100 – 125
– 150 – 170 – 190 –
230 Volts

400 Volts
/
0 – 140 – 180 – 230
– 280 – 400 Volts

 

 

CE

 cRUus

E 214121

 

 UL 1950

Jednofázové transformátory YVT

 

Technical Data
Typ A B C D E F = total
weight
230 / 1,4 78 79 90 56 48 4,8 1,2 kg
230 / 2,1 84 106 95 64 65 4,8 2,0 kg
230 / 3,6 – 400 / 2,0 96 92 105 84 75 5,8 2,5 kg
230 / 4,5 96 106 105 84 75 5,8 2,9 kg
230 / 7,0 120 93 122 90 74 5,8 4,2 kg
400 / 4,0 120 105 122 90 85 5,8 5,2 kg
230 / 10,5 – 400 / 7,0 150 113 148 122 91 7,0 7,8 kg
230 / 16,0 – 400 / 11,0 150 130 148 122 108 7,0 10,2 kg
400 / 16,0 150 155 150 122 133 7,0 13,5 kg
400 / 20,0 174 147 160 138 121 7,0 16,5 kg

F = mounting hole

 

Jednofázový transformátor

 

General Data

First-stage transformers – suitable e.g. for fans. The winding is not galvanically separated according to VDE 0550.

Construction:

Open construction IP 00. Mounting to max. IP 22. Cacuum impregnation in polyester impregnation resin and varnishing. Dimensions according to DIN 41302. Screw connectors with contact protection according to VBG 4.